40 AWG wire size

40 AWG wire is 0.0799 mm (0.00314 in) in diameter with a cross section of 0.00501 mm².

40 AWG specifications

Diameter0.0799 mm · 0.00314 in
Cross section0.00501 mm²
Circular mils0.00989 kcmil
Copper resistance3,440 Ω/km · 1,050 Ω/1000 ft
Aluminium resistance5,630 Ω/km
Nearest metric sizeNo standard metric cable this size

Solid conductor, copper at 20 °C. Values from the standard AWG formula.

Voltage drop example

At 0.5 A over a 10 m run (there and back), 40 AWG copper drops about 34.4 V.

That is 15% of 230 V or 28.7% of 120 V. Many guides aim for under 3%. For your own length and current, use the wire gauge calculator.

What is 40 AWG wire used for?

40 AWG is commonly used for fine electronics, ribbon cables, headphone leads and magnet wire for coils.

Always size wire from your local electrical code and the cable maker’s current rating, which depend on insulation, installation method and temperature. The figures on this page describe the conductor itself.

How does 40 AWG compare with nearby sizes?

The next thicker size is 39 AWG at 0.00632 mm². Every 3 gauge steps roughly halves or doubles the cross section, and every 6 steps roughly halves or doubles the diameter.

Questions about 40 AWG

What is 40 AWG in mm²?

40 AWG has a cross section of 0.00501 mm², from a diameter of 0.0799 mm.

What is the diameter of 40 AWG wire?

A solid 40 AWG conductor is 0.0799 mm, or 0.00314 inches, across. Stranded wire of the same gauge is slightly larger overall.

What is the resistance of 40 AWG copper wire?

About 3,440 ohms per kilometre (1,050 ohms per 1000 ft) for annealed copper at 20 °C. Aluminium of the same size is about 5,630 ohms per kilometre.