26 AWG wire size
26 AWG wire is 0.405 mm (0.0159 in) in diameter with a cross section of 0.129 mm².
26 AWG specifications
| Diameter | 0.405 mm · 0.0159 in |
|---|---|
| Cross section | 0.129 mm² |
| Circular mils | 0.254 kcmil |
| Copper resistance | 134 Ω/km · 40.8 Ω/1000 ft |
| Aluminium resistance | 219 Ω/km |
| Nearest metric size | No standard metric cable this size |
Solid conductor, copper at 20 °C. Values from the standard AWG formula.
Voltage drop example
At 0.5 A over a 10 m run (there and back), 26 AWG copper drops about 1.34 V.
That is 0.582% of 230 V or 1.12% of 120 V. Many guides aim for under 3%. For your own length and current, use the wire gauge calculator.
What is 26 AWG wire used for?
26 AWG is commonly used for fine electronics, ribbon cables, headphone leads and magnet wire for coils.
Always size wire from your local electrical code and the cable maker’s current rating, which depend on insulation, installation method and temperature. The figures on this page describe the conductor itself.
How does 26 AWG compare with nearby sizes?
The next thicker size is 25 AWG at 0.162 mm². The next thinner size is 27 AWG at 0.102 mm². Every 3 gauge steps roughly halves or doubles the cross section, and every 6 steps roughly halves or doubles the diameter.
Questions about 26 AWG
What is 26 AWG in mm²?
26 AWG has a cross section of 0.129 mm², from a diameter of 0.405 mm.
What is the diameter of 26 AWG wire?
A solid 26 AWG conductor is 0.405 mm, or 0.0159 inches, across. Stranded wire of the same gauge is slightly larger overall.
What is the resistance of 26 AWG copper wire?
About 134 ohms per kilometre (40.8 ohms per 1000 ft) for annealed copper at 20 °C. Aluminium of the same size is about 219 ohms per kilometre.