29 AWG wire size
29 AWG wire is 0.286 mm (0.0113 in) in diameter with a cross section of 0.0642 mm².
29 AWG specifications
| Diameter | 0.286 mm · 0.0113 in |
|---|---|
| Cross section | 0.0642 mm² |
| Circular mils | 0.127 kcmil |
| Copper resistance | 268 Ω/km · 81.8 Ω/1000 ft |
| Aluminium resistance | 439 Ω/km |
| Nearest metric size | No standard metric cable this size |
Solid conductor, copper at 20 °C. Values from the standard AWG formula.
Voltage drop example
At 0.5 A over a 10 m run (there and back), 29 AWG copper drops about 2.68 V.
That is 1.17% of 230 V or 2.24% of 120 V. Many guides aim for under 3%. For your own length and current, use the wire gauge calculator.
What is 29 AWG wire used for?
29 AWG is commonly used for fine electronics, ribbon cables, headphone leads and magnet wire for coils.
Always size wire from your local electrical code and the cable maker’s current rating, which depend on insulation, installation method and temperature. The figures on this page describe the conductor itself.
How does 29 AWG compare with nearby sizes?
The next thicker size is 28 AWG at 0.081 mm². The next thinner size is 30 AWG at 0.0509 mm². Every 3 gauge steps roughly halves or doubles the cross section, and every 6 steps roughly halves or doubles the diameter.
Questions about 29 AWG
What is 29 AWG in mm²?
29 AWG has a cross section of 0.0642 mm², from a diameter of 0.286 mm.
What is the diameter of 29 AWG wire?
A solid 29 AWG conductor is 0.286 mm, or 0.0113 inches, across. Stranded wire of the same gauge is slightly larger overall.
What is the resistance of 29 AWG copper wire?
About 268 ohms per kilometre (81.8 ohms per 1000 ft) for annealed copper at 20 °C. Aluminium of the same size is about 439 ohms per kilometre.